via-rhine: fix VLAN priority field (PCP, IEEE 802.1p)
authorRoger Luethi <rl@hellgate.ch>
Sat, 21 Sep 2013 12:24:11 +0000 (14:24 +0200)
committerBen Hutchings <ben@decadent.org.uk>
Sat, 26 Oct 2013 20:06:08 +0000 (21:06 +0100)
[ Upstream commit 207070f5221e2a901d56a49df9cde47d9b716cd7 ]

Outgoing packets sent by via-rhine have their VLAN PCP field off by one
(when hardware acceleration is enabled). The TX descriptor expects only VID
and PCP (without a CFI/DEI bit).

Peter Boström noticed and reported the bug.

Signed-off-by: Roger Luethi <rl@hellgate.ch>
Cc: Peter Boström <peter.bostrom@netrounds.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Signed-off-by: Ben Hutchings <ben@decadent.org.uk>

No differences found