charger-manager: Fix bug related to checking fully charged state of battery
authorChanwoo Choi <cw00.choi@samsung.com>
Thu, 22 Nov 2012 07:53:46 +0000 (16:53 +0900)
committerAnton Vorontsov <anton.vorontsov@linaro.org>
Mon, 17 Dec 2012 06:43:23 +0000 (22:43 -0800)
This patch fix bug related to checking fully charged state of battery when
charger-manager call is_full_charged() function. After reading property of
charger/fuel-gauge through power_supply API, val.intval is more than 1.
So, is_full_charged() function always return true. If true, battery means
fully charged state.

Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>