When the complete device is marked as out of sync, we can disable
updates of the on disk AL. Currently AL updates are only disabled
if one uses the "invalidate-remote" command on an unconnected,
primary device, or when at attach time all bits in the bitmap are
set.
As of now, AL updated do not get disabled when a all bits becomes
set due to application writes to an unconnected DRBD device.
While this is a missing feature, it is not considered important,
and might get added later.
BTW, after initializing a "one legged" DRBD device
drbdadm create-md resX
drbdadm -- --force primary resX
AL updates also get disabled, until the first connect.
Signed-off-by: Philipp Reisner <philipp.reisner@linbit.com>
Signed-off-by: Lars Ellenberg <lars.ellenberg@linbit.com>